Accuracy 0.05% KS803 Three-phase AC/Harmonic Standard Source

Brand Name : Kingsine

Model Number : KS803

Certification : CE/ISO9001

Place of Origin : China

MOQ : 1 set

Price : Negotiation

Payment Terms : L/C,T/T

Supply Ability : 100 sets/month

Delivery Time : 15 working days

Nominal Input Voltage : 115/230Vac appointed, ±10%

Nominal Frequency : 50/60Hz

Working Temperature : 0ºC~40ºC, humidity≤85%RH

Connection Type : Standard AC socket 60320

Dimensions(W x D x H) : 450mm×380mm×190mm

Weight : 25kg

Contact Now

Industry Three Phase 100mA Differential Relay Testing

Description Of Single-phase Power Reference

Applied to Grid Corporation of measurement testing centers, power companies and power plants measured ministries, national institutions at all levels of measurement tests, also applies to the railway, petroleum, chemical industry, large-scale industrial and mining enterprises and the meter manufacturers, etc.

Feature Of Harmonic Standard Power

Applied to Grid Corporation of measurement testing centers, power companies and power plants measured ministries, national institutions at all levels of measurement tests, also applies to the railway, petroleum, chemical industry, large-scale industrial and mining enterprises and the meter manufacturers, etc.
Apply to the power sector, measurement department, quality inspection departments, research institutions, universities, etc.
Applies to other production and research & development enterprise of energy meter, power distribution terminals, power management, load control, power quality, and medium voltage reactive power compensation.
Open communications protocol to facilitate the secondary development for RTU / FTU / Power Management Terminal / Public variable measuring the terminal factory automatic verification.
Calibrating a variety Analog Digital meter of direct U/I instruments & frequency with DC/AC 0.05% accuracy and the corresponding class digital multimeter for quality inspection, measurement and instrumentation maintenance, parts detection
The calibrating types of test instrument including AC-DC voltage meter, ammeter, single / three phase active and reactive power meter, phase meter, power factor meter, frequency tables, synchronized tables, etc.

Specification Of DC Standard source

Output & Measuring AC Voltage
Available Ranges 10V, 30V, 100V, 300V, 750V, auto-shift
Adjustment range 0~120%Rg
Adjustment fineness Range x 0.01%
Resolution Range x 0.01%
Accuracy 0.05%Rg
Stability 0.01% / 1min
Output & Measuring AC Current
Available Ranges 100mA, 1A, 5A, 10A, 25A; auto-shift
Adjustment range 0~120%Rg
Adjustment fineness Range x 0.01%
Resolution Range x 0.01%
Accuracy 0.05%Rg
Stability 0.01% / 1min
Output & Measuring AC Power
Adjustment fineness Range x 0.01%
Resolution Range x 0.01%
Accuracy 0.05%Rg (Factor>0.5)
Stability 0.01% / 1min
Output & Measuring AC Frequency
Frequency Range 45.000~65.000Hz
Adjustment fineness 0.001Hz
Accuracy 0.01%RD
Output & Measuring AC Phase Angle
Phase Angle Range 0.00º~359.99º
Adjustment fineness 0.01º
Resolution 0.01
Accuracy 0.05º
Output & Measuring AC Power Factor
Output Range -1 ~ 0 ~ +1
Measuring Accuracy 0.0005
Adjustment fineness 0.0001
Output & Measuring Harmonic
Harmonic Setting 2~31
Harmonic Content voltage, current ≤30% (as against fundamental)
Harmonic Output Accuracy 0.1% (1st~19th, as against fundamental)
0.2% (20th~31st, as against fundamental)
Harmonic Phase 0~360º, adjustable

Advantage Of Single-phase Power Reference

KS803 Standard Source is fully compatible with the relevant national Standards:

JJG124-93 Verification Regulation of Ammeter, Voltmeter & Ohmmeter
GB/T767-1999 Direct Acting Indicating Analogue Electrical Measuring Instruments & Accessories
SD110-83 Inspection Regulation of Electrical Indicating & Measuring Instruments
JJG440-86 Verification Regulation of Frequency Single Phase Meters
JJG603-89 Verification Regulation of Pointer Frequency Meters

FAQ

Q: How about the guarantee of repair?

A: All of our products have 3-years guarantee of free repair, and life-long maintenance.

Q: What is your technical advantages?

A: Open protocol for software self-programming.AC voltage sources: 3x900V@3x25VA, accuracy 0.05%.AC current sources: 3x30A@3x25VA, accuracy 0.05%.3-phase Harmonic Standard Power: 2-31x orders with 0.1 % accuracy.


Product Tags:

100mA Differential Relay Testing

      

60Hz Differential Relay Testing

      

100mA Differential Relay Tester

      
China Accuracy 0.05% KS803 Three-phase AC/Harmonic Standard Source wholesale

Accuracy 0.05% KS803 Three-phase AC/Harmonic Standard Source Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Kingsine Electric Automation Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)